Greenhouse access bl3 p 1 authorized entry into the greenhouse shall be restricted to individuals who are required for program or support purposes.
Floor plan biosafety level 3 laboratory design.
Carpets and rugs in laboratories are not appropriate.
Biosafety level 3 plants bl3 p appendix l ii c 1.
The uc biosafety level 3 design standards has incorporated input from several of these sources including the following.
Louis encephalitis and west nile virus are examples of agents requiring biosafety level 3 practices and containment.
Basic laboratory design for biosafety levels 1 and 2.
Laboratory furniture must be capable of supporting anticipated loads and uses.
Within the sections specific design criteria are provided.
Spaces between benches cabinets and equipment should be accessible for cleaning.
Cdc biosafety in microbiological and biomedical laboratories bmbl 5th edition 2009 nih design requirements manual for biomedical laboratories and animal research facilities drm 2019.
Standard practices bl3 p a.
The guide is formatted to address laboratory design issues pertinent to general laboratories e g chemical laboratories in section 1 with additional requirements for radioactive materials laboratories and biosafety level 2 laboratories presented in sections 2 and 3 respectively.
The biosafety officer in collaboration with the institutional biosafety committee must approve the location and design of any bsl 3 facility and has final authority to authorize the commencement of bsl 3 work the biosafety level 3 facility design and operational procedures must be documented.
Basic laboratory design for biosafety level 3 basic laboratory design for biosafety levels 1 and 2 up basic laboratory design for biosafety level 3 printer friendly version.
2 these are indigenous or exotic agents that may cause serious or lethal disease via aerosol.
The guide is formatted to address laboratory design issues pertinent to general laboratories e g.
The facility must be tested for verification that the design and operational parameters have been.
Work with these agents is strictly controlled and must be registered with all appropriate government agencies.
The previous wusm laboratory design guidelines combined bsl 2 bsl 3 and absl 3 into one category of high hazard.
The laboratory should be designed so that it can be easily cleaned.
This chapter will provide design and layout information for biosafety level 3 bsl3 laboratories showing how the guidelines translate into three dimensional architectural facilities.
Medicine wusm and its stakeholders with programming and design of new biosafety level 3 bsl 3 and animal biosafety level 3 absl 3 facilities.
Bsl3 laboratory with anteroom or workroom as access zone.