The span table for a 30 psf live load 10psf dead load floor indicates a required fb value of 1 315 and a minimum e value of 1 800 000.
Floor load limit aircraft.
Above limit load intensity 2 500 1 45 344 8 above limit for box 2.
Furthermore certain types of uld most specifically 16 and 20 foot pallets have specific maximum.
It is calculated by dividing the load by the area it covers.
Floor loading is the weight of a load ill pounds divided by the area of floor space which the load occupies.
For example an observer on board an aircraft performing a turn with a load factor of 2 i e.
Floor running load or linear load.
The aircraft floor is a precision engineered structure any excess of concentrated mass in one location can cause damage to this structure both endangering the safety of the aircraft and leading to expensive and extensive repairs to the aircraft.
An amount of weight higher than this amount is assumed to damage the uld and hence endanger the safety of the aircraft.
It does not mean that a 300 lb.
The standard used by lufthansa is 2000 kg per square meter.
Lineman standing on one leg will fall through the floor.
Base of container 20 in x 20 in 400 sq in floor loading 100 lb 0 2 lb per sq in 400 sq in or 0 25 lb sq in x 144 36 ib sq ft.
For example a floor joist at 16 spacing s that can carry 53 pounds per linear foot would translate into a 318 pound single point load at its.
It is calculated as the weight of the object divided by the distance it covers along the aircraft s length.
If a mass of 50 kg is spread over 1 square metre the distribution load is 50 1 50 kg sq meter.
Box 2 was already ruled out.
The maximum weight the floor can sustain per square inch foot as provided by the manufacturer.
Floor load capacity limit is the maximum permissible load per square meter.
A320 214 structural weight limit kg 3402 4536 1497 9435 max floor limit 488 kg m2 732 kg m2 amount of akh volume 3 6m3 3 2 2 max gross weight of akh on all positions 1134 kg table 2 cargo capacities.
The floor loading for a 100 pound container is determined as follows.
Calculating distribution load intensity.
A 2 g turn will see objects falling to the floor at twice the normal acceleration of gravity.
A uniform load rating on a beam can easily be translated into what an equivalent maximum point load can be.
Either of boxes 3 and 4 with their longest length parallel to the aircraft longitudinal axis correct.
14 cfr 1 1 16g abbreviation acronym aerodynamics aircraft airline airlines airport airports airworthiness amt atc aviation safety aviation weather avionics bird strike engineering etops faa faa pilot s handbook flying human.
For 1 sq meter area in contact with the floor the limit is 731 for 0 8 sq meter the limit is 731 x 0 81 585 kgs.
In general whenever the term load factor is used it is formally correct to express it using numbers only as in a maximum load factor of 4.